Curved Austral pavilions designed and manufactured by Okatent

If you are looking for a highly resistant textile cover to cover a sport space that fits standard sizes from regulatory fields, this is the tent for you.

   

Curved Austral pavilion main features:

curvados1

The Curved Austral pavilion is the tent with the most resistant structure of all the Okatent catalog, its curved form is designed to support different environments and assembly types.

Its design shows a soft and adaptable esthetic which can be used for every event and company types that look for a both resistant and esthetic tent. It is mainly designed to cover sports facilities, industrial units, playgrounds, advertising and aeronautics events.

The Curved pavilion model has 14 standard sizes to choose from and it’s the favorite model to cover paddle courts.

curvados2

  • Tent designed, manufactured and assembled by Okatent
  • Perfect for covering sports facilities
  • Highly resistant to weather conditions
  • PVC cover with waterproof and fire-resistant membrane
  • Built in a modular way with no length limit
  • Lone, plate or sandwich panel enclosures.
  • Curved tent set up in less than 72 hours
  • Removable and transportable structure
  • Diaphanous interiors with no central pillars
  • No building permits needed
  • With European quality certificates
  • 4 years extensive warranty

Technical characteristics:

Curved pavilion with reinforced aluminum structure, quick assembly and extensive customization options.

The Curved pavilion has different junctions and profiles designed for each one of the tent’s sizes and loads of each structure.

Características Pabellón Austral Curvado

  • 10×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 10m
    • Lateral height: 3m
    • Total height: 4,34m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 10m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 129x67x3mm
    • Lintel size: 129x67x3mm

  • 10×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 10m
    • Lateral height: 4m
    • Total height: 5,34m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 10m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 201x106x3mm
    • Lintel size: 201x106x3mm

  • 15×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 15m
    • Lateral height: 3m
    • Total height: 5,09m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 15m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 201x106x3mm
    • Lintel size: 201x106x3mm

  • 15×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 15m
    • Lateral height: 4m
    • Total height: 6,09m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 15m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 201x106x3mm
    • Lintel size: 201x106x3mm

  • 20×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 20m
    • Lateral height: 3m
    • Total height: 5,75m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 20m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 201x106x3mm
    • Lintel size: 201x106x3mm

  • 20×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 20m
    • Lateral height: 4m
    • Total height: 6,75m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 20m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 203x109x4mm
    • Lintel size: 203x109x4mm

  • 25×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 25m
    • Lateral height: 3m
    • Total height: 7,09m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 25m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 203x109x4mm
    • Lintel size: 203x109x4mm

  • 25×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 25m
    • Lateral height: 4m
    • Total height: 7,57m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 25m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 226x112x10mm
    • Lintel size: 226x112x10mm

  • 30×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 30m
    • Lateral height: 3m
    • Total height: 7,35m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 30m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 226x112x10mm
    • Lintel size: 226x112x10mmm

  • 30×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 30m
    • Lateral height: 4m
    • Total height: 8,35m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 30m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 226x112x10mm
    • Lintel size: 226x112x10mmm

  • 40×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 40m
    • Lateral height: 3m
    • Total height: 8,72m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 40m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 226x112x10mm
    • Lintel size: 226x112x10mmm

  • 40×4 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 40m
    • Lateral height: 4m
    • Total height: 9,72m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 40m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 285x112x10mm
    • Lintel size: 285x112x10mmm

  • 50×3 meters Pavilion:

    TECHNICAL DATA

    • Entrance portico: 50m
    • Lateral height: 3m
    • Total height: 10,34m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 50m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: 285x112x10mm
    • Lintel size: 285x112x10mmm

  • 50×4 metros Pavilion (without profiles):

    TECHNICAL DATA

    • Entrance portico: 50m
    • Lateral height: 4m
    • Total height: 11,34m
    • Roof inclination: 18º
    • Modular lateral distance: 5m
    • Minimum length: 50m
    • Longest component: 12.5m
    • Maximum length:
    • Wind resistance: 110km/h
    • Supported load: 0.2 kN/m2
    • Set up time: 225m2 in 4 hours

    Calculated according to temporal structures, tents and security NORM UNE-EN 13782-2005. Made for standard structure.

    PROFILE DETAIL

    • Strut size: 106x75mm
    • Strap size: 106x65mm
    • Pillar size: n/e
    • Lintel size: n/e

Since we are direct manufacturers you have the possibility to choose any other size or customization and it will be designed by our technical team.

Estructura de aluminio

Aluminium structure

Aluminium structure

The aluminum used to manufacture one-gabled austral pavilions is made of an alloy 6082T6 and is extruded at high pressure with first class aluminum. The surface finish is anodized 15 microns and suitable for the protection of the structure outdoors. Once the aluminum structure has reached the end of its lifetime it can be entirely recycled and reused.
Lonas pabellones

Covers and laterals fabric

Covers and laterals fabric

Polyester fabric covered on one side with PVC M2 certified according to the UNE 23723:90
Normative. High density polyester cover and lateral curtains, waterproof and fire-resistant certified by APPLUS. 500D PVC Coat Fabric material of 360g/m2 grammage and 0,36mm thickness.
Certificado Applus

Canvas certificate

Canvas certificate

The membrane used for the closures is made of polyester fabric covered with transparent and waterproof PVC: white color VALMEX 8212 RAL 9010 with a M2 grade according to NORMA NFP 82507 fire-proof protection, with 650gr/m2 weight and 250/250N resistance to warp/weft tear.
Materiales reciclables

Environment and recycling

Environment and recycling

At Okatent, year by year, we pretend to minimize or eliminate our industrial activity impact on the environment; and this is why many of our products are recycled at the end of their lifetime. We don’t use polluting products in the manufacturing of our canvas or structures and the labeling inks are eco-solvent.

Lateral closure option

Choose the lateral closure option for your gabled tent. In the Okatent catalog you will find up to 5 lateral closure standard options: Simple canvas, Opaque canvas, plate lateral, sandwich panel, transparent laterals.

  • Simple canvas laterals: The membrane used for the closures is made of a polyester fabric covered with transparent fire-resistant and waterproof PVC
  • Opaque canvas laterals: The closure is made of a simple membrane of polyester covered with acrylic varnish PVC on two sides and alma negra inside.
  • Sandwich panel lateral: Self-supporting metallic panel isolated in polyurethane, destined to industrial units walls, commercial buildings and compartments in general.
  • Transparent laterals: The transparent canvas is made of a transparent membrane manufactured with polyester fabric covered with translucent PVC

Covers types opcions

Choose the cover type for your gabled tent upper closure. Choose one of the 5 options that Okatent offers thinking about the closure and isolation needs: Simple canvas cover, Opaque canvas cover, Transparent cover, Pressurized cover.

  • Simple canvas cover: The cover is made of a simple membrane of polyester covered with PVC on two sides composed of welded Keder on the opposite lateral sides to ensure tightness with the structure.
  • Opaque canvas cover: The cover is made of a simple membrane of polyester covered with acrylic varnish PVC on two sides and alma negra inside, composed of welded Keder on the opposite lateral sides to ensure tightness with the structure.
  • Transparent cover: The transparent cover is made of a transparent membrane manufactured with polyester fabric covered with translucent PVC.
  • Pressurized cover: Cover with membrane covered with two PVC canvas layers creating an air chamber with a constant pressure between 0.8 and 1.2 mbar and a 1.5 thermal insulation factor.

Accesorios disponibles para el Pabellón Austral a dos aguas

Ask for more information about Curved Austral pavilion Now!

We have prepared an interesting promotion just for you fill in the following form:

Other similar pavilions manufactured by Okatent